Insulation Material For 10kV And Below Peroxide XLPE Cables - KABLO-10KV-VE-ALTI-PEROKSIT-XLPE-KABLOLAR-ICIN-YALITIM-MALZEMESI

Part Number: KABLO-10KV-VE-ALTI-PEROKSIT-XLPE-KABLOLAR-ICIN-YALITIM-MALZEMESI
Alternative Cross Numbers: 3901909000
Category: Cable Raw Materials

Description

Home / Cables / Wire and Cable

T/T, L/C, D/P, etc.

10 days

By Sea

Shanghai, China

3901909000

12 Months

Insulation Material for 10kV and below Peroxide XLPE Cables which regards advanced LDPE resin as the main raw material, adds antioxidant, cross-linking agent and other accessory ingredients, is manufactured by advanced closed extruding equipment. It has excellent extrusion property and physical property, its impurity content is controlled within limits. This product is mainly used as the insulation of medium-low voltage cross-linking cables. Long-term working temperature is 90℃.

Recommend to process with the PE extruder

 

Specifications

Payment & Delivery
  • Payment Terms:
  • Delivery Time:
  • Shipping:
  • Port of Loading:
  • HS Code:
  • Storage:
Technical Table 1
ModelMachine Barrel TemperatureMolding Temperature
OW-YJ-10100-115℃110-115℃
Technical Table 2
No.ItemUnitTechnical Requirements
1Densityg/cm³0.922±0.003
2Tensile StrengthMPa≥13.5
3Elongation at Break%≥350
4Brittle Temperature with Low Temperature-76
520℃ Volume ResistivityΩ·m≥1.0×10¹⁴
620℃ Dielectric Strength,50HzMV/m≥25.0
720℃ Dielectric Constant,50Hz≤2.35
820℃ Dielectric Dissipation Factor,50Hz≤0.001
9Impurity Content (Per 1.0Kg)
0.175-0.250mm
≥0.250 mm
(No.)
(No.)
––
10Air Aging Condition
135℃×168h
Tensile Strength Variation
After Aging
%≤±20
Elongation Variation After Aging%≤±20
11Hot Set Test Condition
200℃×0.2MPa×15min
Hot Elongation%≤80
Note: More specifications, please contact our sales  staff.